| ... with own bearings |
OG 6 |
| Square-wave cycles per turn: | 100 - 512 |  | Servo flange |
| Max. output frequency: | 120 kHz | Solid shaft d= 6 mm |
| Logic level: | HTL (C), TTL, TTL (R) | |
| Permissible encoder temperature: | -20 °C to +70 °C | |
| Connection: | Internal connection terminals | |
| Weight: | approx. 200 g | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 54 | Ex II 3G 3D |
| |
OG 60 • HOG 60 |
| Square-wave cycles per turn: | max. 10,000 |  | Servo flange (OG 60) |
| Max. output frequency: | 250 kHz | Solid shaft d= 6 mm (OG 60) |
| Logic level: | HTL (C), TTL, TTL (R) | Hollow shaft with clamping ring up to d= 12 mm (HOG 60) |
| Permissible encoder temperature: | -30 °C to +85 °C |
| Connection: | Plug connection | High resolution |
| Weight: | approx. 260 g (OG 60) approx. 250 g (HOG 60) | |
| Shock resistance (6 ms): | 3,000 m/s² | |
| Protection class: | IP 65 | Ex II 3G 3D |
| |
OG 70 • HOG 70 |
| Square-wave cycles per turn: | 50 - 10,000 |  | Servo flange (OG 70) |
| Max. output frequency: | 250 kHz | Solid shaft d= 6 mm (OG 70) |
| Logic level: | HTL (C), TTL, TTL (R) | Hollow shaft up to d= 14 mm (HOG 70) |
| Permissible encoder temperature: | -20 °C to +85 °C |
| Connection: | Internal connection terminals | |
| Weight: | approx. 360 g (OG 70) approx. 240 g (HOG 70) | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
OG 71 • HOG 71 |
| Square-wave cycles per turn: | OG 71: 100 up to 1,024 HOG 71: 64 up to 2,048 |  | Servo flange (OG 71) |
| Max. output frequency: | 120 kHz | Solid shaft d= 6 mm (OG 71) |
| Logic level: | HTL (C), TTL, TTL (R) | Hollow shaft up to d= 14 mm (HOG 71) |
| Permissible encoder temperature: | -20 °C to +85 °C |
| Connection: | Internal terminal strip | |
| Weight: | approx. 360 g (OG 71) approx. 240 g (HOG 71) | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
AHE 7 • AFE 7 |
| Square-wave cycles per turn: | 60 - 5,000 |  | Version US of OG 71/•HOG 71 |
| Max. output frequency: | 120 kHz | 1/2" hollow shaft (AHE 7) |
| Logic level: | HTL (C), TTL, TTL (R) | 3/8" servo flange (AFE 7) |
| Permissible encoder temperature: | -30 °C to +70 °C | NPT 1/2" fitting |
| Connection: | Internal connection terminals | |
| Weight: | approx. 240 g (AHE 7) approx. 380 g (AFE 7) | |
| |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 56 | |
| |
HOG 75 • HOG 75 K |
| Square-wave cycles per turn: | 250 - 2,500 |  | Through-hole hollow shaft with clamping ring up to d= 26 mm (HOG 75) |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL | Cone shaft 1:10 (HOG 75 K) |
| Permissible encoder temperature: | -30 °C to +85 °C | |
| Connection: | Internal connection terminals | |
| Weight: | approx. 320 g | |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
OG 8 • HOG 8 |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11mm (OG 8) |
| Max. output frequency: | 120 kHz | Through-hole hollow shaft with clamping ring up to d= 16 mm (HOG 8) |
| Logic level: | HTL (C), TTL, TTL (R) |
| Permissible encoder temperature: | -30 °C to +85 °C | |
| Connection: | Internal connection terminals | |
| Weight: | approx. 700 g (OG 8) approx. 550 g (HOG 8) | |
| |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 54 | |
| |
OG 9 |
| Square-wave cycles per turn: | 1 - 1,250 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -30 °C to +100 °C | |
| Connection: | Terminal box | |
| Weight: | approx. 900 g | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 55 | Ex II 3G 3D |
| |
OG 90 |
| Square-wave cycles per turn: | 1,000 - 10,000 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 250 kHz | High HTL output current |
| Logic level: | HTL (C), TTL, TTL (R) | High resolution |
| Permissible encoder temperature: | -30 °C to +85 °C | |
| Connection: | Terminal box | |
| Weight: | approx. 1.5 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 55 | |
| |
HOG 9 • HOG 9 G |
| Square-wave cycles per turn: | 1 - 2,500 |  | Hollow shaft with clamping element up to d= 16 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Option: Cone shaft 1:10 |
| Permissible encoder temperature: | -30 °C to +100 °C | High HTL output current |
| Connection: | Plug connection | Bearing at each end |
| Weight: | approx. 700 g (HOG 9) | Protection against shaft currents |
| | approx. 1,100g (HOG 9G) | Twin encoder HOG 9 G |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
FOG 9 |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -30 °C to +100 °C | |
| Connection: | Plug connection | |
| Weight: | approx. 860 g | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
POG 9 |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -30 °C to +100 °C | Twin encoder POG 9 G |
| Connection: | Terminal box | |
| Weight: | approx. 1.3 kg | |
| Shock resistance (1 ms): | 3,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
POG 9 G |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -30 °C to +100 °C | |
| Connection: | Terminal box | |
| Weight: | approx. 1.7 kg | |
| Shock resistance (1 ms): | 3,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
POG 90 |
| Square-wave cycles per turn: | 1,024 - 10,000 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 250 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -20 °C to +85 °C | High resolution |
| Connection: | large terminal box | |
| Weight: | approx. 1.5 kg | |
| Shock resistance (11 ms): | 1,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
HOG 10 |
| Square-wave cycles per turn: | 1 - 2,500 |  | Hollow shaft with clamping element up to d= 20 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Option: Cone shaft 1:10 |
| Permissible encoder temperature: | -40 °C to +100 °C -50 °C to +100 °C (optional) | High HTL output current |
| Connection: | Internal connection terminals or large terminal box | Protection against shaft currents |
| Weight: | approx. 1.6 kg | Twin encoder HOG 10 G |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
HOG 10 G |
| Square-wave cycles per turn: | 1 - 2,500 |  | Hollow shaft with clamping element up to d= 20 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Option: Cone shaft 1:10 |
| Permissible encoder temperature: | -40 °C to +100 °C -50 °C to +100 °C (optional) | High HTL output current |
| Connection: | Large terminal box | Protection against shaft currents |
| Weight: | approx. 2.2 kg | |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
HOG 100 |
| Square-wave cycles per turn: | 1,024 - 10,000 |  | Hollow shaft with clamping element up to d= 16 mm |
| Max. output frequency: | 250 kHz |
| Logic level: | HTL, TTL | Option: Cone shaft 1:10 |
| Permissible encoder temperature: | -30 °C to +85 °C | High HTL output current |
| Connection: | Internal connection terminals or large terminal box | High resolution |
| Weight: | approx. 1.5 kg | Protection against shaft currents |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
POG 10 |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -40 °C to +100 °C -50 °C to +100 °C (optional) | Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
| Connection: | Large terminal box |
| Weight: | approx. 1.6 kg | Twin encoder POG 10 G |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 66 | |
| Ex II 3G 3D |
| |
POG 10 G |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | High HTL output current |
| Logic level: | HTL, TTL, TTL (R) | Bearing at each end |
| Permissible encoder temperature: | -40 °C to +100 °C -50 °C to +100 °C (optional) | Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
| Connection: | Large terminal box |
| Weight: | approx. 2.4 kg | |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 66 | |
| Ex II 3G 3D |
| |
HOG 11 (Offshore) |
| Square-wave cycles per turn: | 1 - 2,500 |  | Hollow shaft with clamping element up to d= 16 mm |
| Max. output frequency: | 120 kHz | Option: Cone shaft 1:10 |
| Logic level: | HTL, TTL, TTL (R) | Protection against inductive shaft currents |
| Permissible encoder temperature: | -30 °C to +100 °C | Special corrosion protection e.g. for offshore |
| Connection: | Large terminal box | Option: Hybrid bearing |
| Weight: | approx. 1.6 kg | Option: Earthing brush for capacitive shaft currents |
| Shock resistance (6 ms): | 2,500 m/s² | Option: Heating for use down to -55°C |
| Twin encoder HOG 11 G |
| Protection class: | IP 67 | Ex II 3G 3D |
| |
HOG 11 G (Offshore) |
| Square-wave cycles per turn: | 1 - 2,500 |  | Hollow shaft with clamping element up to d= 16 mm |
| Max. output frequency: | 120 kHz | Option: Cone shaft 1:10 |
| Logic level: | HTL, TTL, TTL (R) | Protection against inductive shaft currents |
| Permissible encoder temperature: | -30 °C to +100 °C | Special corrosion protection e.g. for offshore |
| Connection: | Large terminal box | Option: Hybrid bearing |
| Weight: | approx. 2.2 kg | Option: Earthing brush for capacitive shaft currents |
| Option: Heating for use down to -55°C |
| Shock resistance (6 ms): | 2,500 m/s² | |
| Protection class: | IP 67 | Ex II 3G 3D |
| |
POG 11 (Offshore) |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
| Logic level: | HTL, TTL, TTL (R) |
| Permissible encoder temperature: | -30 °C to +100 °C | Special corrosion protection e.g. for offshore |
| Connection: | Large terminal box | Option: Hybrid bearing |
| Weight: | approx. 1.8 kg | Option: Heating for use down to -55°C |
| Shock resistance (6 ms): | 3,000 m/s² | Twin encoder POG 11 G |
| Protection class: | IP 67 | Ex II 3G 3D |
| |
POG 11 G (Offshore) |
| Square-wave cycles per turn: | 1 - 2,500 |  | EURO flange B10, solid shaft d= 11 mm |
| Max. output frequency: | 120 kHz | Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
| Logic level: | HTL, TTL, TTL (R) |
| Permissible encoder temperature: | -30 °C to +100 °C | Special corrosion protection e.g. for offshore |
| Connection: | Large terminal box | Option: Hybrid bearing |
| Weight: | approx. 2.4 kg | Option: Heating for use down to -55°C |
| Shock resistance (6 ms): | 3,000 m/s² | |
| Protection class: | IP 67 | Ex II 3G 3D |
| |
HOG 12 |
| Square-wave cycles per turn: | 600, 1,024 |  | Through-hole hollow shaft with clamping ring up to d= 45 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL (C), TTL, TTL (R) |
| Permissible encoder temperature: | -30 °C to +85 °C | |
| Connection: | Cable connection | |
| Weight: | approx. 1 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 54 | |
| |
HOG 131 (Offshore) |
| Square-wave cycles per turn: | 1,024 - 3,072 |  | Through-hole hollow shaft with clamping ring up to d= 36 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) |
| Permissible encoder temperature: | -40 °C to +100 °C | |
| Connection: | Large terminal box | |
| Weight: | approx. 4 kg | |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
EGZ 14 • AG 14 |
| Square-wave cycles per turn: | 250 - 2,500 |  | Through-hole hollow shaft up to d= 70 mm |
| Max. output frequency: | 120 kHz | Especially for lift drives |
| Logic level: | HTL (C), TTL, TTL (R) | |
| Permissible encoder temperature: | -30 °C to +70 °C | |
| Connection: | Plug connection (EGZ 14) Terminal box or plug connection (AG 14) | |
| Weight: | approx. 1.2 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 20, IP 54 | |
| |
HOG 16 |
| Square-wave cycles per turn: | 250 - 2,500 |  | Through-hole hollow shaft with clamping element up to d= 38 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | High HTL output current |
| Permissible encoder temperature: | -20 °C to +100 °C | Slip-ring earthing contact |
| Connection: | Terminal box | Option: Redundant scanning |
| Weight: | approx. 4 kg | |
| Shock resistance (6 ms): | 3,000 m/s² | |
| Protection class: | IP 66 | Ex II 3G 3D |
| |
HOG 161 |
| Square-wave cycles per turn: | 250 - 2,048 |  | Through-hole hollow shaft with clamping ring up to d= 75 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Option: Redundant scanning |
| Permissible encoder temperature: | -20 °C to +85 °C | |
| Connection: | Terminal box | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 54 | |
| | | Ex II 3G 3D |
| |
HOG 163 (Offshore) |
| Square-wave cycles per turn: | 250 - 5,000 |  | Through-hole hollow shaft with clamping ring up to d= 75 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Insulated bearings |
| Permissible encoder temperature: | -30 °C to +85 °C | Special corrosion protection |
| Connection: | Large terminal box | Option: Redundant scanning |
| Weight: | approx. 3.5 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 56 | Ex II 3G 3D |
| |
HOG 165 (Offshore) |
| Square-wave cycles per turn: | 250 - 5,000 |  | Hollow shaft with clamping element up to d= 38 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Special corrosion protection |
| Permissible encoder temperature: | -30 °C to +100 °C | Option: Protection against shaft currents |
| Connection: | Large terminal box | Option: Slip-ring earthing contact |
| Weight: | approx. 4 kg | Option: Redundant scanning |
| Shock resistance (6 ms): | 3,000 m/s² | |
| Protection class: | IP 67 | Ex II 3G 3D |
| |
HOG 22 • HOG 220 |
| Square-wave cycles per turn: | HOG 22: (720 - 4,000) HOG 220: (1,024) |  | Through-hole hollow shaft with clamping ring up to d= 115 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HOG 22: HTL (C), TTL, TTL (R) HOG 220: HTL, TTL, TTL (R) | |
| Permissible encoder temperature: | -30 °C to +85 °C | |
| Connection: | Terminal box or plug connection | |
| Weight: | approx. 8.8 kg | |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | HOG 22: IP 54 HOG 220: IP 56 | Ex II 3G 3D |
| |
HOG 28 |
| Square-wave cycles per turn: | 1,024 - 2,048 |  | Through-hole hollow shaft up to d= 150 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL (C), TTL, TTL (R) | |
| Permissible encoder temperature: | -30 °C to +85 °C | |
| Connection: | Plug connection | |
| Weight: | approx. 20 kg | |
| Shock resistance (6 ms): | 2,000 m/s² | |
| Protection class: | IP 54 | Ex II 3G 3D |
| |
HML 131 M |
| Square-wave cycles per turn: | 128 - 2,048 |  | Hollow shaft up to d= 36 mm |
| Max. output frequency: | 200 kHz | Operable under oil |
| Logic level: | HTL (C), TTL, TTL (R) |
| Permissible encoder temperature: | -20 °C to +90 °C | Magnetic sensing |
| Connection: | Special connector | Redundant sensing |
| Weight: | approx. 2.2 kg | |
| Shock resistance (12 ms): | 2,000 m/s² | |
| Protection class: | IP 68 | |
| |
| ... without own bearings |
| |
HG 6 |
| Square-wave cycles per turn: | 100 - 512 |  | Servo flange |
| Max. output frequency: | 120 kHz | Hollow shaft up to d= 16 mm |
| Logic level: | HTL (C), TTL, TTL (R) | Rugged construction without own bearings for very high speeds |
| Permissible encoder temperature: | -20 °C to +85°C |
| Connection: | Internal connection terminals | Incremental disk protected in axial and radial direction |
| Weight: | approx. 180 g |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 56 / IP 23 | Without own bearings |
| |
HG 16 |
| Square-wave cycles per turn: | 250 - 2,500 |  | Through-hole hollow shaft with clamping ring up to d= 45 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL, TTL, TTL (R) | Axial displacement max. - 0.5 mm, +1.5 mm Option: up to +2.5 mm |
| Permissible encoder temperature: | -30 °C to +100°C |
| Connection: | Terminal box, Option: Plug connection | Option: Redundant scanning |
| Weight: | approx. 2.4 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 56 | Without own bearings |
| |
HG 18 • HG 22 |
| Square-wave cycles per turn: | HG 18: 250 - 2,500 HG 22: 720 - 4,000 |  | Through-hole hollow shaft with clamping ring up to d= 110 mm |
| Max. output frequency: | 120 kHz |
| Logic level: | HTL (C), TTL, TTL (R) | Axial displacement max. - 0.5 mm, +1.5 mm Option: up to +2.5 mm |
| Permissible encoder temperature: | -30 °C to +70°C |
| Connection: | Terminal box, Option: Plug connection | Option: Redundant scanning |
| Weight: | HG 18: approx. 4.2 kg HG 22: approx. 5.8 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | HG 18: IP 54, HG 22: IP 44 | Without own bearings |
| |
HG 21 • HG 211 |
| Square-wave cycles per turn: | 2,500 |  | Through-hole hollow shaft up to d= 95 mm |
| Max. output frequency: | 120 kHz Option: 160 kHz |
| Logic level: | HTL (C), TTL, TTL (R) | Axial displacement max. - 0.5 mm, +1.5 mm Option: up to +2.5 mm |
| Permissible encoder temperature: | -30 °C to +70 °C |
| Connection: | Connector | Option: redundant scanning |
| Weight: | approx. 5.8 kg | |
| Shock resistance (6 ms): | 1,000 m/s² | |
| Protection class: | IP 44 | Without own bearings |
| |
HMC 16 (M) + HEAG 158 V (M) |
| Square-wave cycles per turn: | 128 - 8,192 |  | Hollow shaft up to d= 55 mm |
| Max. output frequency: | 2,000 kHz | Magnetic sensing |
| Logic level: | HTL, TTL |
| Permissible encoder temperature: | -30 °C / 0 °C to +70 °C / 105 °C | Redundant sensing (optional) |
| Connection: | 12 pin mating connector (male contacts) | |
| Weight: | approx. 2.4 kg | |
| Shock resistance (12 ms): | 3,000 m/s² | |
| Protection class: | HMC 16 (M) - IP 68 HEAG 158 V (M) - IP 65 | |
| |
MHGE 100 B5 |
| Square-wave cycles per turn: | 64 ... 4096 |  | Through-hole hollow shaft with d= 20 ... 80 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -40 °C up to +100 °C | Option: additional incremental signals |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHGE 200 B5 |
| Square-wave cycles per turn: | 128 ... 8192 |  | Through-hole hollow shaft with d= 50 ... 180 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -40 °C up to +100 °C | Option: additional incremental signals |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHGE 400 B5 |
| Square-wave cycles per turn: | 256 ... 16384 |  | Through-hole hollow shaft with d= 100 ... 380 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -40 °C up to +100 °C | Option: additional incremental signals |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHGE 800 B5 |
| Square-wave cycles per turn: | 512 ... 32768 |  | Through-hole hollow shaft with d= 380 ... 740 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -40 °C up to +100 °C | Option: additional incremental signals |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHGP 100 B5 |
| Square-wave cycles per turn: | 64, 128, ... 1024, ... 131072 |  | Through-hole hollow shaft with d= 20 ... 80 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -20 °C up to +85 °C | Option: Error output |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHGP 200 B5 |
| Square-wave cycles per turn: | 128, 256, ... 1024, ... 262144 |  | Through-hole hollow shaft with d= 50 ... 180 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -20 °C up to +85 °C | Option: Error output |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHGP 400 B5 |
| Square-wave cycles per turn: | 256, 512, 1024, ... 524288 |  | Through-hole hollow shaft with d= 100 ... 380 mm |
| Logic level: | HTL, TTL | Large permissible axial displacement |
| Max. output frequency: | 300 kHz | Large permissible air gap tolerance |
| Permissible encoder temperature: | -20 °C up to +85 °C | Option: Error output |
| Connection: | 12 pole flange socket (ccw, pins) | |
| Vibration resistance (55 Hz ... 2000 Hz): | 300 m/s² | |
| Shock resistance (2 ms): | 3.000 m/s² | |
| Protection class: | wheel IP 68 / head IP 67 | |
| |
MHG 100 Download... |
| Square-wave cycles per turn: | 64 - 1,024 |  | Through-hole hollow shaft up to d= 80 mm |
| Maximum speed: | 4,000 rpm |
| Logic level: | HTL | Tangential magnetic sensing |
| Permissible encoder temperature: | -40 °C to +85 °C | Large mounting tolerances |
| Moment of inertia: | approx. 17 kgcm² | |
| Shock resistance (12 ms): | 2,000 m/s² | |
| Protection class: | IP 68 | Without own bearings |
| |
MHG 150 Download... |
| Square-wave cycles per turn: | 94 - 1,504 |  | Through-hole hollow shaft up to d= 130 mm |
| Maximum speed: | 4,000 rpm, Option: 12,000 rpm |
| Logic level: | TTL | Tangential magnetic sensing |
| Permissible encoder temperature: | -40 °C to +85 °C | Large mounting tolerances |
| Moment of inertia: | approx. 18.4 kgcm² (d=130 mm, without marker pulse) approx. 33.67 kgcm² (d=130 mm, with marker pulse) | Option: Marker pulse |
| |
| Shock resistance (12 ms): | 2,000 m/s² | |
| Protection class: | IP 68 | Without own bearings |
| |
MHG 400 Download... |
| Square-wave cycles per turn: | 256 - 2,048 |  | Through-hole hollow shaft up to d= 380 mm |
| Maximum speed: | 3,000 rpm |
| Logic level: | HTL, TTL | Operation possible under oil or water |
| Permissible encoder temperature: | -20 °C to +95 °C | Tangential magnetic sensing |
| Moment of inertia: | approx. 1,118 kgcm² (d=380 mm) | Large mounting tolerances |
| Shock resistance (12 ms): | 2,000 m/s² | Option: Special corrosion protection |
| Protection class: | IP 68 | Option: Cover |
| | | Without own bearings |
| |
| Technical modifications reserved. |